Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan.


Abstract
Aims: To evaluate the postulate that a combination of x-ray mammography (XMM) and scintimammography (SMM) using receiver operatinq characteristic (ROC) statistical technique is better than either imaging used alone in the diagnosis of early breast cancer. <br><br> Methods: A cohort of 27 patients with 30 breast tumours was studied prospectively. The patients underwent a clinical examination, XMM,j and SMM, followed by fine needle biopsy/excision biopsy. The findings on XMM and SMM were divided into five grades: (1) probably normal, (2) probably benign, (3) equivocal, (4) probably malignant and (5) definitely malignant. Sensitivity and specificity were determined and ROC curves were drawn for XMM and SMM and compared against combined XMM and SMM. <br><br> Results: The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for XMM were calculated at 77%, 82%, 77% and 82% respectively; 85%, 94%, 92% and 89% for SMM; and for combined XMM and SMM, the values were 92%, 94%, 92% and 94% respectively. ROC curves were drawn and analysis of areas under ROC curves yielded values for XMM, SMM and combined imaging (XMM+SMM) at 0.85, 0.90 and 0.93 respectively. Wilcoxon signed ranked test showed that p value for XMM and result of combination images (XMM+SMM) was close to significant at 95% confidence level (i.e. 0.06) and the p value for SMM and combination imaqes (XMM+SMM) was also close to significant at 95% confidence level (i.e. 0.062). The p value for XMM and SMM was not significant. <br><br> Conclusion: The study shows that a combination of XMM and SMM, is more accurate in the diagnosis of early breast cancer than XMM or SMM alone. The study further suggests a role for SMM in equivocal breast lesions documented on XMM.


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Zahid Rahman Khan
Articles by Shoab Shah
Articles by Afshan Zahid Khan
on Google
on Google Scholar

How to Cite this Article
Pubmed Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan. Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography. Pak J Nucl Med. 2012; 2(1): 45-54.


Web Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan. Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography. https://www.pjnmed.com/?mno=284630 [Access: February 27, 2024].


AMA (American Medical Association) Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan. Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography. Pak J Nucl Med. 2012; 2(1): 45-54.



Vancouver/ICMJE Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan. Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography. Pak J Nucl Med. (2012), [cited February 27, 2024]; 2(1): 45-54.



Harvard Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan (2012) Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography. Pak J Nucl Med, 2 (1), 45-54.



Turabian Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan. 2012. Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography. Pakistan Journal of Nuclear Medicine, 2 (1), 45-54.



Chicago Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan. "Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography." Pakistan Journal of Nuclear Medicine 2 (2012), 45-54.



MLA (The Modern Language Association) Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan. "Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography." Pakistan Journal of Nuclear Medicine 2.1 (2012), 45-54. Print.



APA (American Psychological Association) Style

Zahid Rahman Khan, Shoab Shah, Afshan Zahid Khan (2012) Advantages of ROC analysis in the diagnosis of breast tumours using combined x-ray mammography and scintimammography. Pakistan Journal of Nuclear Medicine, 2 (1), 45-54.





Most Viewed Articles
Most Accessed Articles

  • Determination of the optimum filter for 99mTc SPECT breast imaging using a wire mesh collimator
    Xianling Dong, M I Saripan, R Mahmud, S Mashohor, Aihui Wang
    Pak J Nucl Med. 2017; 7(1): 9-15
    » Abstract » doi: 10.24911/PJNMed.7.2

  • Behaviour of wedges for different field sizes and depths
    Sajjad Ahmed Memon, Naeem Ahmed Laghari, Fayaz Hussain Mangi
    Pak J Nucl Med. 2017; 7(1): 20-27
    » Abstract » doi: 10.24911/PJNMed.7.4

  • Pre-operative cardiac risk stratification for noncardiac surgery in cancer patients using myocardial perfusion scintigraphy
    Iqbal Munir, Amrah Javaid, Khalid Nawaz, Mohammed Hathaf Al-Rowaily, Muaadh Abdualrehman Al-Asbahi
    Pak J Nucl Med. 2017; 7(1): 28-33
    » Abstract » doi: 10.24911/PJNMed.7.5

  • Clinical characteristics and long-term outcome of patients with differentiated carcinoma of thyroid with bone metastases: a retrospective study
    Sadaf Tufail Butt, Shazia Fatima, Noreen Marwat, Kahkashan Mir, Ayesha Ammar, Mohammad Faheem
    Pak J Nucl Med. 2017; 7(1): 34-37
    » Abstract » doi: 10.24911/PJNMed.7.6

  • A brief review of targetted radionuclide therapies
    Mohammed Hathaf Al-Rowaily, Daniele Dondi, MarcoChinol, Iqbal Munir, Muaadh Abdualrehman Alasbahi
    Pak J Nucl Med. 2017; 7(1): 4-8
    » Abstract » doi: 10.24911/PJNMed.7.1

  • Most Downloaded
    Top Downloaded Articles

  • Behaviour of wedges for different field sizes and depths
    Sajjad Ahmed Memon, Naeem Ahmed Laghari, Fayaz Hussain Mangi
    Pak J Nucl Med. 2017; 7(1): 20-27
    » Abstract » doi: 10.24911/PJNMed.7.4

  • Determination of the optimum filter for 99mTc SPECT breast imaging using a wire mesh collimator
    Xianling Dong, M I Saripan, R Mahmud, S Mashohor, Aihui Wang
    Pak J Nucl Med. 2017; 7(1): 9-15
    » Abstract » doi: 10.24911/PJNMed.7.2

  • Characterization of SIEMENS Symbia T SPECT camera in Monte Carlo simulation environment
    Xianling Dong, Mahmud Iqbal Saripan, Rozi Mahmud, Syamsiah Mashohor, Aihui Wang,
    Pak J Nucl Med. 2018; 8(1): 18-26
    » Abstract » doi: 10.24911/PJNMed.175-1540569779

  • A historic review of the discovery of the medical uses of radioiodine
    Barbara Hertz, Pushan Bharadwaj, Bennett Greenspan
    Pak J Nucl Med. 2020; 10(1): 60-63
    » Abstract » doi: 10.24911/PJNMed.175-1582813482

  • A brief review of targetted radionuclide therapies
    Mohammed Hathaf Al-Rowaily, Daniele Dondi, MarcoChinol, Iqbal Munir, Muaadh Abdualrehman Alasbahi
    Pak J Nucl Med. 2017; 7(1): 4-8
    » Abstract » doi: 10.24911/PJNMed.7.1

  • Most Cited Articles
    Most Cited Articles